Sabine Pass LNG (U.S.): 6 active notices, 2 rated severity 4–5; 0 posted in the last 7 days. 1 outage in effect today (no volume stated) at Gillis Compressor Station, expected back Dec 31. Capacity Offline →
Free: this page refreshes several times a day (delayed) — email & Telegram alerts on a 1-hour delay, severity 4–5 only.
Pro ($149/mo): Real-time alerts within ~2 minutes of posting, full AI trading note. See plans →
Maintenance0.400 Bcf/d cut (capped at 1.530 Bcf/d)Until Further Notice6 Days
CTPL 2026 Q4 maintenance summary (updated 10/15/26) bundles two jobs at Gillis Compressor Station. The highest-impact job is Job 2026115, a 6-day Station Upgrade (11/12-11/18/2026) that reduces available capacity to zero transport impact (0 Dths transport impact) with available capacity of 1,530,000 Dths and a TETCO (CT109413) meter capacity limit set to 0, effectively cutting one feed interconnect entirely. The lesser job, 2026114, is a 15-hour compressor maintenance event (11/17/2026) with a 400,000 Dth/day transport impact and 1,130,000 Dths available capacity.
Job 2026115 Station Upgrade at Gillis Compressor Station (11/12-11/18, 6 days) sets TETCO CT109413 meter limit to zero and posts zero transport impact Dths with 1.530 Bcf/d available capacity, reducing feedgas flexibility at Sabine Pass LNG and applying bearish pressure on Henry Hub as export throughput is constrained during the upgrade window.
Reroute: None: Sabine Pass LNG is the delivery endpoint; no alternative pipeline can substitute for LNG feedgas curtailed at the Gillis terminal interconnect during the station upgrade.
This is a bundled CTPL 2026 Planned Outage and Maintenance Summary covering two independent jobs. The most impactful single job is Job 2026114 (Q4): a 15-hour compressor maintenance window at Gillis Compressor Station on 11/17/2026 (3:00 a.m. to 6:00 p.m.), with a transport impact of 400,000 Dths (0.400 Bcf/d) and available capacity reduced to 1,130,000 Dths. Job 2026112 (Q3, 9/29-10/2, 4 days) is a LEAP Meter Station upgrade with zero transport impact and should not be treated as a capacity-affecting event.
Job 2026114 removes 0.400 Bcf/d of Sabine Pass LNG feedgas capacity for ~15 hours on 11/17/2026, reducing available CTPL throughput to 1.130 Bcf/d; LNG feedgas curtailment keeps that volume in the domestic market, bearish Henry Hub for that gas day, with the Gillis-LEAP interconnect (CT109461) currently scheduled at 0.735 Bcf/d against 1.00 Bcf/d operating capacity providing partial buffer.
Reroute: Limited: CTPL is the dedicated feed gas pipeline for Sabine Pass LNG; no alternative pipeline directly replaces CTPL feedgas supply to the terminal, though Cheniere may partially offset the 15-hour window through storage or scheduling adjustments.
This is Revision 2 of CTPL's 2026 Q3 planned outage and maintenance summary for Creole Trail Pipeline serving Sabine Pass LNG. The most impactful single job is Job 2026111: Gillis Compressor Station compressor maintenance running 8/25/2026 3:00 a.m. through 8/28/2026 6:00 p.m. (4 days, Gas Days 24-28), with a stated transport impact of 130,000 Dths/day (0.130 Bcf/d) against an available capacity of 1,400,000 Dths/day. The two updated Job 2026113 entries (LEAP Meter Station filter changeouts on 9/8 and 9/9, 9 hours each) show zero transport impact and a meter capacity limit of 475,000 Dths/day at CT109461. Job 2026112 (LEAP Meter Station upgrades 9/29-10/2, 4 days) also shows zero transport impact.
The dominant job in this posting removes 0.130 Bcf/d of CTPL feedgas transport capacity to Sabine Pass LNG for 4 days beginning 8/25/2026; expect mild bearish pressure at Henry Hub as that volume stays in the domestic market, with the CT200111-CREOLE TRAIL-SPLIQ-D delivery point currently running at 88.4% utilization (1.50 Bcf/d scheduled against 1.70 Bcf/d operating capacity), leaving roughly 0.197 Bcf/d of headroom that partially absorbs the constraint.
Reroute: None: CTPL is the dedicated pipeline serving Sabine Pass LNG, and the constraint reduces feedgas transport capacity directly to the terminal with no bypass route available for the curtailed volumes.
View original notice text
Loading…
About Sabine Pass LNG
The Sabine Pass LNG export terminal. Its feedgas pipelines (including Creole Trail) and their compressor stations are what its notices cover; an outage there cuts LNG feedgas.
Operated by
Cheniere Energy
Runs
Cameron Parish, Louisiana
Trading points
Henry Hub, Gulf Coast LNG
Mapped facilities
Gillis
Line from EIA pipeline data; dots are facilities named in this pipeline’s notices (HIFLD locations). Dashed lines are schematic.